GreenTherm Plus
Heating & Cooling Heat Pump
PHNIX GreenTherm Plus Series is an AI-powered R290 residential air-to-water heat pump for house heating, cooling and domestic hot water. It combines efficient everyday performance with AI-driven control, quiet operation and service-friendly design, making it a competitive choice for mainstream new-build and home renovation projects.
Product Details
-
Natural R290 RefrigerantA lower-impact refrigerant solution for future-ready residential heating. -
High Energy EfficiencyA+++ energy efficiency at both 35°C and 55°C, with a SCOP of up to 5.1. -
Year-Round PerformanceStable operation from -25°C to 45°C for dependable winter comfort. -
Outlet Water Temperature Up to 75°CGreater flexibility for underfloor heating, radiators and domestic hot water. -
Quiet OperationSound pressure as low as 35 dB(A) at 1 m. -
Multilingual Smart ControlSrandard display is available in 13 languages. And the optional display is available in 16 languages with integrated room temperature and humidity. -
AI Smart AssistantNIKIGPT supports device control, product guidance and preliminary troubleshooting. -
Professional AIoT ManagementCentralised fleet, operating and service management through the PHNIX AIoT platform and GoHeating Pro.
-
AI Intelligent ControlAI Full Inverter TechnologyBuilt on operating data from more than 25,000 installed heat pumps, PHNIX AI Full Inverter Technology adjusts compressor frequency and expansion-valve control to match real-time demand more precisely. Dynamic-tariff adaptation and intelligent scheduling further reduce unnecessary operation, delivering more than 30% energy savings while maintaining stable indoor comfort. -
AI Smart DefrostingConventional defrosting can interrupt warmth and consume energy even when it is not needed. GreenTherm Plus monitors ambient temperature, humidity and actual frost conditions to determine the right time to defrost. Fewer unnecessary defrost cycles mean more consistent winter comfort, lower energy consumption and reliable operation in freezing weather. -
Built-In R290 SafetyGreenTherm Plus combines an integrated gas separator with a potted control board and optional high-precision R290 leak detection. The gas separator captures and vents gas and microbubbles from the water circuit, while the protected PCB helps resist moisture, insects and corrosion. Together, these safeguards support safer indoor heating integration and more dependable long-term operation. -
Designed for Easier Installation & ServiceAn optimised water circuit reduces water resistance by up to 5 kPa, supporting smoother circulation and more efficient heat exchange. Convenient side access makes terminal wiring and PCB replacement easier, while the potted control board protects critical electronics against moisture, insects, corrosion and short circuits. This practical structure helps reduce installation complexity and simplify service throughout the product lifecycle. -
Hybrid Energy IntegrationReady to work with photovoltaic systems, dynamic electricity tariffs and new or existing boilers.
Product parameters
| Model | / | L15 | L20 | L30 | L30S | L40 | L40S | L50 | L50S | L60 | L60S | L80S |
| Power Supply | / | 220-240V~/50Hz | 220-240V~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz | 380~415V/3N~/50Hz |
| Heating Condition - Ambient Temp. (DB/WB): 7/6°C, Water Temp. (In/Out): 30/35°C | ||||||||||||
| Nominal Heating Capacity | kW | 4 | 6 | 10 | 9 | 12 | 12 | 14 | 14 | 17 | 17 | 20 |
| Heating Capacity Range | kW | 1.40-6.00 | 1.40-7.07 | 4.5-12.0 | 4.5-12.0 | 4.5-16.0 | 4.5-16.0 | 4.5-17.5 | 4.5-17.5 | 4.6-20.0 | 4.6-20.0 | 6.7-23.6 |
| Heating Power Input Range | kW | 0.25-1.33 | 0.25-1.60 | 0.78-2.70 | 0.78-2.70 | 0.78-3.76 | 0.78-3.76 | 0.78-4.85 | 0.78-4.85 | 1.02-5.1 | 1.02-5.10 | 1.02-5.97 |
| Heating Condition - Ambient Temp. (DB/WB): 7/6°C, Water Temp. (In/Out): 47/55°C | ||||||||||||
| Nominal Capacity | kW | 4 | 6 | 9 | 9 | 10 | 10 | 12 | 12 | 15 | 15 | 18 |
| Heating Capacity Range | kW | 1.30-5.50 | 1.30-6.50 | 4.3-12.0 | 4.3-12.0 | 4.3-15.0 | 4.3-15.0 | 4.3-16.5 | 4.3-16.5 | 6.3-19.2 | 6.3-19.2 | 6.3-21.6 |
| Heating Power Input Range | kW | 0.36-1.72 | 0.36-2.13 | 1.2-3.93 | 1.2-3.93 | 1.2-5.26 | 1.2-5.26 | 1.2-6.00 | 1.2-6.00 | 2.1-6.37 | 2.1-6.37 | 2.1-7.63 |
| Cooling Condition - Ambient Temp. (DB/WB): 35/24°C, Water Temp. (In/Out): 23/18°C | ||||||||||||
| Nominal Cooling Capacity | kW | 4 | 6 | 8 | 8 | 9.95 | 9.89 | 9.95 | 9.89 | 11.2 | 10.9 | 10.9 |
| Cooling Power Input Range | kW | 0.33-2.06 | 0.33-2.19 | 0.8-3.90 | 0.8-3.90 | 0.8-4.46 | 0.8-4.46 | 0.8-5.6 | 0.8-5.6 | 1.24-5.01 | 1.24-5.01 | 1.24-6.28 |
| Cooling Condition - Ambient Temp. (DB/WB): 35/24°C, Water Temp. (In/Out): 12/7°C | ||||||||||||
| Nominal Cooling Capacity | kW | 4 | 6 | 8 | 8 | 10 | 10 | 10 | 10 | 11.2 | 10.9 | 10.9 |
| Cooling Power Input Range | kW | 0.34-1.73 | 0.34-1.84 | 1.0-3.15 | 1.0-3.15 | 1.0-3.86 | 1.0-3.86 | 1.0-4.78 | 1.0-4.78 | 1.14-4.50 | 1.14-4.50 | 1.14-5.42 |
| Max. Power Input | kW | 2.65 | 3 | 5.5 | 5.5 | 6.3 | 6.3 | 6.3 | 6.3 | 8.48 | 8.57 | 8.57 |
| Max. Current Input | A | 11.5 | 13 | 23.7 | 8.7 | 27 | 10 | 27 | 10 | 37 | 12 | 12 |
| Refrigerant Type | / | R290 | ||||||||||
| Refrigerant Volume | kg | 0.28 | 0.28 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | 0.75 | 0.75 | 0.75 |
| Sound Pressure (lm) | dB(A) | 39 | 40 | 44 | 44 | 45 | 45 | 46 | 46 | 48 | 48 | 50 |
| Sound Power Level (EN12102) | dB(A) | 49 | 50 | 54 | 54 | 54 | 54 | 55 | 55 | 56 | 56 | 57 |
| Net Weight | kg | 66 | 66 | 105 | 105 | 105 | 107 | 105 | 107 | 137 | 139 | 139 |
| Unit Dimension(L/W/H) | mm | 1000×420×700 | 1000×420×700 | 1260×490×922 | 1260×490×922 | 1260×490×922 | 1260×490×922 | 1260×490×922 | 1260×490×922 | 1260×490×1335 | 1260×490×1335 | 1260×490×1335 |
| Shipping Dimension(L/W/H) | mm | 1040×420×845 | 1040×420×845 | 1300×495×1065 | 1300×495×1065 | 1300×495×1065 | 1300×495×1065 | 1300×495×1065 | 1300×495×1065 | 1300×495×1480 | 1300×495×1480 | 1300×495×1480 |
| Circulation Pump | / | YES | ||||||||||
| Operating Ambient Temperature | °C | -25~45 | ||||||||||
| Fan Motor Type | / | DC Fan Motor | ||||||||||
| Water Connection | inch | 1 | ||||||||||
| Rated Water Flow | m³/h | 0.69 | 1.03 | 1.55 | 1.55 | 2.06 | 2.06 | 2.41 | 2.41 | 2.92 | 2.92 | 3.44 |
| Water Pressure Drop @Rated Water Flow | kPa | 10 | 15 | 25 | 25 | 35 | 35 | 40 | 40 | 53 | 53 | 73 |
| Circulation Pump Head @Rated Water Flow | m | 5 | 4.3 | 6 | 6 | 5.5 | 5.5 | 5 | 5 | 6 | 6 | 4 |
| Cabinet Type | / | Sheet Metal | ||||||||||