GreenTherm Pro
Heating & Cooling Heat Pump
PHNIX GreenTherm Pro Series is a premium R290 air-to-water heat pump for house heating, cooling and domestic hot water. Its P20 model delivers an independently verified SCOP of 5.55, while EVI technology enables reliable heating down to -30°C and water output of up to 80°C. Full-lineup RED certification, AI early intervention and built-in R290 protection make it a flagship solution for demanding European new-build and renovation markets.
Product Details
-
Natural R290 RefrigerantA lower-impact refrigerant solution for future-ready residential heating. -
Verified Premium EfficiencyA+++ energy efficiency at both 35°C and 55°C, with a SCOP of 5.55 verified by HLK Stuttgart. -
EVI Cold-Climate PerformanceReliable operation from -30°C to 45°C for dependable comfort in demanding climates. -
Outlet Water Temperature Up to 80°CGreater flexibility for modern heating systems and higher-temperature renovation projects. -
Low Operation NoiseSound pressure as low as 31 dB(A) at 1 m for greater residential installation flexibility. -
Built-In System ProtectionRefrigerant leak detection and an integrated gas separator enhance protection across both refrigerant and water circuits. -
TÜV SÜD RED CertifiedThe complete GreenTherm Pro lineup is RED certified for connected European applications. -
AI-driven Service ManagementProfessional fleet management through PHNIX AIoT and GoHeating Pro, with convenient home control through the AI WarmLink app.
-
Verified Efficiency & Full RED ComplianceGreenTherm Pro turns premium efficiency into independently verified performance. Its P20 model achieves a SCOP of 5.55 under ErP 35°C conditions, verified by HLK Stuttgart—an EN ISO 17025-accredited laboratory at the University of Stuttgart. Together with TÜV SÜD RED certification across the full lineup, it is ready for the efficiency, connectivity and compliance expectations of today’s European residential HVAC market. -
Built-In R290 SafetyGreenTherm Pro makes R290 safety an integral part of the system. Built-in leak detection responds quickly to abnormal refrigerant levels, while the integrated gas separator removes gas and microbubbles from the water circuit. This coordinated protection brings greater confidence to installation and greater peace of mind to everyday home heating. -
AI Early InterventionThe New Era of Proactive Service 3.0GreenTherm Pro transforms after-sales service from reactive repair into proactive care. More than 12 predictive monitoring modes cover over 50 potential fault conditions, allowing the system to identify abnormalities and issue early alerts before failures occur. Service teams gain more time to plan maintenance, while homeowners benefit from more reliable and constant heating. -
Installation with Multifunctional Tank -
Installation with EasyHydro
Product parameters
| Model | P20 | P40 | P40S | P60 | P60S | |
| Power Supply | / | 220-240V~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz | 220-240V~/50Hz | 380~415V/3N~/50Hz |
| Heating Condition - Ambient Temp. (DB/WB): 7/6℃, Water Temp. (In/Out): 30/35℃ | ||||||
| Nominal Heating Capacity | kW | 6 | 12 | 12 | 17 | 17 |
| Heating Capacity Range | kW | 1.90-6.38 | 4.29-12.80 | 4.46-12.80 | 6-18.5 | 6-18.5 |
| Heating Power Input Range | kW | 0.44-1.27 | 0.70-2.74 | 0.74-2.74 | 1.3-5.58 | 1.3-5.58 |
| Heating Condition - Ambient Temp. (DB/WB): 7/6℃, Water Temp. (In/Out): 47/55℃ | ||||||
| Nominal Capacity | kW | 6 | 12 | 12 | 17 | 17 |
| Heating Capacity Range | kW | 1.06-6.72 | 4.35-12.16 | 4.25-12.16 | 6~18 | 6~18 |
| Heating Power Input Range | kW | 0.65-2.12 | 0.94-3.80 | 0.92-3.80 | 1.8-5.45 | 1.8-5.45 |
| Cooling Condition - Ambient Temp. (DB/WB): 35/24℃, Water Temp. (In/Out): 23/18℃ | ||||||
| Cooling Capacity Range | kW | 2.05-10.05 | 4.63-17.99 | 4.63-17.99 | 6.0-23.0 | 6.0-23.0 |
| Cooling Power Input Range | kW | 0.53-2.62 | 0.91-5.38 | 0.91-5.38 | 1.3-7.3 | 1.3-7.3 |
| Cooling Condition - Ambient Temp. (DB/WB): 35/24℃, Water Temp. (In/Out): 12/7℃ | ||||||
| Cooling Capacity Range | kW | 1.12-6.82 | 3.44-14.14 | 3.44-14.14 | 4~17 | 4~18 |
| Cooling Power Input Range | kW | 0.57-2.54 | 1.01-5.14 | 1.01-5.14 | 1.7-7.1 | 1.7-7.2 |
| Max. Power Input | kW | 3.5 | 6.09 | 6.09 | 8.74 | 10.4 |
| Max. Current Input | A | 15.5 | 26.68 | 8.91 | 38 | 15 |
| Refrigerant Type | / | R290 | R290 | R290 | R290 | R290 |
| Refrigerant Volume | kg | 0.7 | 1 | 1 | 1.3 | 1.3 |
| Sound Pressure (1m) | dB(A) | 39 | 42 | 42 | 46 | 45 |
| Sound Power Level (EN12102) | dB(A) | 48 | 51 | 51 | 53 | 51 |
| Net Weight | kg | 133 | 145 | 148 | 191 | 200 |
| Unit Dimension(L/W/H) | mm | 1370×590×915 | 1370×590×915 | 1370×590×915 | 1370×590×1335 | 1370×590×1335 |
| Shipping Dimension(L/W/H) | mm | 1490×610×1050 | 1490×610×1050 | 1490×610×1050 | 1490×610×1470 | 1490×610×1470 |
| Circulation Pump | / | Yes | Yes | Yes | Yes | Yes |
| Operating Ambient Temperature | ℃ | -30~45 | -30~45 | -30~45 | -30~45 | -30~45 |
| Fan Motor Type | / | DC motor | DC motor | DC motor | DC motor | DC motor |
| Water Connection | inch | 1 | 1 | 1 | 1 | 1 |
| Rated Water Flow | m³/h | 1.03 | 2.06 | 2.06 | 2.92 | 2.92 |
| Water Pressure Drop @Rated Water Flow | kPa | 12 | 23 | 23 | 40 | 40 |
| Circulation Pump Head @Rated Water Flow | m | 7 | 7.8 | 7.8 | 10.4 | 10.4 |
| Cabinet type | / | Alloy | Alloy | Alloy | Alloy | Alloy |